Power Conditioning
-
Power |
---|
Output voltage regulation | 10% |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.5 kVA |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Off-mode charging | Yes |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 240 V |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Input frequency | 50/60 Hz |
Package type | Box |
Ports & interfaces |
---|
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 2 |
Off-mode charging | Yes |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Battery recharge time | 6 h |
Cold start | Yes |
Battery recharge time(90%) | 6 h |
Design |
---|
Form factor | Mini Tower |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE, EAC |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS & user manual |
Manual | Yes |
Package type | Box |
Package width | 190 mm |
Package depth | 390 mm |
Package height | 275 mm |
Weight & dimensions |
---|
Package type | Box |
Package width | 190 mm |
Package depth | 390 mm |
Package height | 275 mm |
Weight | 10.4 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 320 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS & user manual |
Packaging content |
---|
Manual | Yes |
Packaging content | UPS & user manual |
FSP FP 1500 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA 900 W 4 AC outlet(s) Power |
---|
Output voltage regulation | 10% |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 240 V |
Output power capacity | 1.5 kVA |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Off-mode charging | Yes |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 900 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 240 V |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Input frequency | 50/60 Hz |
Package type | Box |
Ports & interfaces |
---|
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 2 |
Off-mode charging | Yes |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Battery recharge time | 6 h |
Cold start | Yes |
Battery recharge time(90%) | 6 h |
Design |
---|
Form factor | Mini Tower |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE, EAC |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS & user manual |
Manual | Yes |
Package type | Box |
Package width | 190 mm |
Package depth | 390 mm |
Package height | 275 mm |
Weight & dimensions |
---|
Package type | Box |
Package width | 190 mm |
Package depth | 390 mm |
Package height | 275 mm |
Weight | 10.4 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 320 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS & user manual |
Packaging content |
---|
Manual | Yes |
Packaging content | UPS & user manual |
£142.56 Out of stock
-
Power |
---|
Output power | 480 W |
Input operation voltage (min) | 180 V |
Input operation voltage (max) | 270 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Output power capacity | 0.8 kVA |
Battery |
---|
Battery type | 9 AH |
Number of batteries supported | 1 |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Battery recharge time | 8 h |
Typical backup time at full load | 15 min |
Performance |
---|
UPS topology | Standby (Offline) |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Overcharge, Overdischarge, Overload |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
UPS topology | Standby (Offline) |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
Output power | 480 W |
Input operation voltage (min) | 180 V |
Input operation voltage (max) | 270 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Power protection features | Overcharge, Overdischarge, Overload |
Audible alarm(s) | Yes |
Output power capacity | 0.8 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces |
---|
Number of type F outputs | 2 |
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
Design |
---|
Form factor | Compact |
LED indicators | Yes |
Product colour | Black |
Technical details |
---|
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions |
---|
Package width | 288 mm |
Package depth | 120 mm |
Package height | 280 mm |
Weight | 3.1 kg |
Width | 82.5 mm |
Height | 207 mm |
Depth | 228 mm |
Packaging data |
---|
Package width | 288 mm |
Package depth | 120 mm |
Package height | 280 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Battery type | 9 AH |
Nominal output voltage | 220 V |
FSP Nano 800 uninterruptible power supply (UPS) Standby (Offline) 0.8 kVA 480 W 2 AC outlet(s) Power |
---|
Output power | 480 W |
Input operation voltage (min) | 180 V |
Input operation voltage (max) | 270 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Output power capacity | 0.8 kVA |
Battery |
---|
Battery type | 9 AH |
Number of batteries supported | 1 |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Battery recharge time | 8 h |
Typical backup time at full load | 15 min |
Performance |
---|
UPS topology | Standby (Offline) |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Overcharge, Overdischarge, Overload |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
UPS topology | Standby (Offline) |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
Output power | 480 W |
Input operation voltage (min) | 180 V |
Input operation voltage (max) | 270 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Power protection features | Overcharge, Overdischarge, Overload |
Audible alarm(s) | Yes |
Output power capacity | 0.8 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces |
---|
Number of type F outputs | 2 |
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
Design |
---|
Form factor | Compact |
LED indicators | Yes |
Product colour | Black |
Technical details |
---|
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions |
---|
Package width | 288 mm |
Package depth | 120 mm |
Package height | 280 mm |
Weight | 3.1 kg |
Width | 82.5 mm |
Height | 207 mm |
Depth | 228 mm |
Packaging data |
---|
Package width | 288 mm |
Package depth | 120 mm |
Package height | 280 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Battery type | 9 AH |
Nominal output voltage | 220 V |
£81.38 Out of stock
-
Power |
---|
Output voltage regulation | 10% |
Output power | 1200 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 240 V |
Output power capacity | 2 kVA |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Off-mode charging | Yes |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 1200 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 240 V |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 2 kVA |
Input frequency | 50/60 Hz |
Package type | Box |
Ports & interfaces |
---|
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 2 |
Off-mode charging | Yes |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Battery recharge time | 6 h |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 6 h |
Design |
---|
Form factor | Mini Tower |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE, EAC |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS & user manual |
Manual | Yes |
Package type | Box |
Package width | 190 mm |
Package depth | 390 mm |
Package height | 275 mm |
Packaging content |
---|
Batteries included | Yes |
Manual | Yes |
Packaging content | UPS & user manual |
Weight & dimensions |
---|
Package type | Box |
Package width | 190 mm |
Package depth | 390 mm |
Package height | 275 mm |
Weight | 11 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 320 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS & user manual |
FSP FP 2000 uninterruptible power supply (UPS) Line-Interactive 2 kVA 1200 W 4 AC outlet(s) Power |
---|
Output voltage regulation | 10% |
Output power | 1200 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 240 V |
Output power capacity | 2 kVA |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Off-mode charging | Yes |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 1200 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 240 V |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 2 kVA |
Input frequency | 50/60 Hz |
Package type | Box |
Ports & interfaces |
---|
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 2 |
Off-mode charging | Yes |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Battery recharge time | 6 h |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 6 h |
Design |
---|
Form factor | Mini Tower |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE, EAC |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS & user manual |
Manual | Yes |
Package type | Box |
Package width | 190 mm |
Package depth | 390 mm |
Package height | 275 mm |
Packaging content |
---|
Batteries included | Yes |
Manual | Yes |
Packaging content | UPS & user manual |
Weight & dimensions |
---|
Package type | Box |
Package width | 190 mm |
Package depth | 390 mm |
Package height | 275 mm |
Weight | 11 kg |
Width | 130 mm |
Height | 182 mm |
Depth | 320 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS & user manual |
£187.57 Out of stock
-
Power |
---|
Output voltage regulation | 10% |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Output power capacity | 0.6 kVA |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Off-mode charging | Yes |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.6 kVA |
Input frequency | 50/60 Hz |
Package type | Box |
Ports & interfaces |
---|
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 1 |
Off-mode charging | Yes |
Battery voltage | 12 V |
Battery capacity | 7 Ah |
Battery recharge time | 6 h |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Mini Tower |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE, EAC |
Packaging data |
---|
Packaging content | UPS & user manual |
Manual | Yes |
Package type | Box |
Package width | 324 mm |
Package depth | 140 mm |
Package height | 220 mm |
Packaging content |
---|
Batteries included | Yes |
Manual | Yes |
Packaging content | UPS & user manual |
Weight & dimensions |
---|
Package type | Box |
Package width | 324 mm |
Package depth | 140 mm |
Package height | 220 mm |
Weight | 4.25 kg |
Width | 110 mm |
Height | 145 mm |
Depth | 294 mm |
Other features |
---|
Packaging content | UPS & user manual |
FSP FP 600 uninterruptible power supply (UPS) Line-Interactive 0.6 kVA 360 W 2 AC outlet(s) Power |
---|
Output voltage regulation | 10% |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Output power capacity | 0.6 kVA |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Off-mode charging | Yes |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 360 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.6 kVA |
Input frequency | 50/60 Hz |
Package type | Box |
Ports & interfaces |
---|
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 1 |
Off-mode charging | Yes |
Battery voltage | 12 V |
Battery capacity | 7 Ah |
Battery recharge time | 6 h |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Mini Tower |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE, EAC |
Packaging data |
---|
Packaging content | UPS & user manual |
Manual | Yes |
Package type | Box |
Package width | 324 mm |
Package depth | 140 mm |
Package height | 220 mm |
Packaging content |
---|
Batteries included | Yes |
Manual | Yes |
Packaging content | UPS & user manual |
Weight & dimensions |
---|
Package type | Box |
Package width | 324 mm |
Package depth | 140 mm |
Package height | 220 mm |
Weight | 4.25 kg |
Width | 110 mm |
Height | 145 mm |
Depth | 294 mm |
Other features |
---|
Packaging content | UPS & user manual |
£82.46 Out of stock
-
Power |
---|
Output voltage regulation | 10% |
Output power | 480 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 220 V |
Output power capacity | 0.8 kVA |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Off-mode charging | Yes |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 480 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 220 V |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.8 kVA |
Input frequency | 50/60 Hz |
Package type | Box |
Ports & interfaces |
---|
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 1 |
Off-mode charging | Yes |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Battery recharge time | 6 h |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Mini Tower |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE, EAC |
Packaging data |
---|
Packaging content | UPS & user manual |
Manual | Yes |
Package type | Box |
Package width | 324 mm |
Package depth | 140 mm |
Package height | 220 mm |
Packaging content |
---|
Batteries included | Yes |
Manual | Yes |
Packaging content | UPS & user manual |
Weight & dimensions |
---|
Package type | Box |
Package width | 324 mm |
Package depth | 140 mm |
Package height | 220 mm |
Weight | 4.9 kg |
Width | 110 mm |
Height | 145 mm |
Depth | 294 mm |
Other features |
---|
Packaging content | UPS & user manual |
FSP FP 800 uninterruptible power supply (UPS) Line-Interactive 0.8 kVA 480 W 2 AC outlet(s) Power |
---|
Output voltage regulation | 10% |
Output power | 480 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 220 V |
Output power capacity | 0.8 kVA |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Off-mode charging | Yes |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Line-Interactive |
Waveform | Sine |
Output voltage regulation | 10% |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Response time | 6 ms |
Output power | 480 W |
Input operation voltage (min) | 162 V |
Input operation voltage (max) | 290 V |
Output operation voltage (min) | 100 V |
Output operation voltage (max) | 220 V |
Power protection features | Battery discharge, Overcharge, Overload |
Noise level | 40 dB |
Audible alarm(s) | Yes |
Output power capacity | 0.8 kVA |
Input frequency | 50/60 Hz |
Package type | Box |
Ports & interfaces |
---|
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 1 |
Off-mode charging | Yes |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Battery recharge time | 6 h |
Cold start | Yes |
Automatic battery test | Yes |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Mini Tower |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE, EAC |
Packaging data |
---|
Packaging content | UPS & user manual |
Manual | Yes |
Package type | Box |
Package width | 324 mm |
Package depth | 140 mm |
Package height | 220 mm |
Packaging content |
---|
Batteries included | Yes |
Manual | Yes |
Packaging content | UPS & user manual |
Weight & dimensions |
---|
Package type | Box |
Package width | 324 mm |
Package depth | 140 mm |
Package height | 220 mm |
Weight | 4.9 kg |
Width | 110 mm |
Height | 145 mm |
Depth | 294 mm |
Other features |
---|
Packaging content | UPS & user manual |
£72.70 Out of stock
-
Power |
---|
Output power | 360 W |
Input operation voltage (min) | 180 V |
Input operation voltage (max) | 270 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Output power capacity | 0.6 kVA |
Performance |
---|
UPS topology | Standby (Offline) |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Overcharge, Overdischarge, Overheating, Short circuit |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
UPS topology | Standby (Offline) |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
Output power | 360 W |
Input operation voltage (min) | 180 V |
Input operation voltage (max) | 270 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Power protection features | Overcharge, Overdischarge, Overheating, Short circuit |
Audible alarm(s) | Yes |
Output power capacity | 0.6 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces |
---|
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 1 |
Battery voltage | 12 V |
Battery capacity | 7 Ah |
Battery recharge time | 8 h |
Typical backup time at full load | 10 min |
Design |
---|
Form factor | Compact |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Weight & dimensions |
---|
Package width | 288 mm |
Package depth | 120 mm |
Package height | 280 mm |
Weight | 2.7 kg |
Width | 82.5 mm |
Height | 207 mm |
Depth | 228 mm |
Packaging data |
---|
Package width | 288 mm |
Package depth | 120 mm |
Package height | 280 mm |
FSP Nano 600 uninterruptible power supply (UPS) Standby (Offline) 0.6 kVA 360 W 2 AC outlet(s) Power |
---|
Output power | 360 W |
Input operation voltage (min) | 180 V |
Input operation voltage (max) | 270 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Output power capacity | 0.6 kVA |
Performance |
---|
UPS topology | Standby (Offline) |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
LED indicators | Yes |
Power protection features | Overcharge, Overdischarge, Overheating, Short circuit |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
UPS topology | Standby (Offline) |
Waveform | Sine |
Auto-restart | Yes |
Response time | 6 ms |
Output power | 360 W |
Input operation voltage (min) | 180 V |
Input operation voltage (max) | 270 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 220 V |
Power protection features | Overcharge, Overdischarge, Overheating, Short circuit |
Audible alarm(s) | Yes |
Output power capacity | 0.6 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces |
---|
AC outlets quantity | 2 AC outlet(s) |
AC outlet types | Type F |
Battery |
---|
Number of batteries supported | 1 |
Battery voltage | 12 V |
Battery capacity | 7 Ah |
Battery recharge time | 8 h |
Typical backup time at full load | 10 min |
Design |
---|
Form factor | Compact |
LED indicators | Yes |
Product colour | Black |
Operational conditions |
---|
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Weight & dimensions |
---|
Package width | 288 mm |
Package depth | 120 mm |
Package height | 280 mm |
Weight | 2.7 kg |
Width | 82.5 mm |
Height | 207 mm |
Depth | 228 mm |
Packaging data |
---|
Package width | 288 mm |
Package depth | 120 mm |
Package height | 280 mm |
£61.23 In stock
-
Power |
---|
Output voltage regulation | ±10%% |
Output frequency regulation | ±1 Hz |
Output power | 480 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.8 kVA |
Performance |
---|
UPS topology | Standby (Offline) |
Waveform | Sine |
Response time | 6 ms |
Surge protection | Yes |
Surge protection features | Network |
Power protection features | Overcharge, Overdischarge, Overload |
Noise level | 40 dB |
Features |
---|
Output frequency | 50/60 Hz |
UPS topology | Standby (Offline) |
Waveform | Sine |
Output voltage regulation | ±10%% |
Output frequency regulation | ±1 Hz |
Response time | 6 ms |
Output power | 480 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge protection | Yes |
Surge protection features | Network |
Power protection features | Overcharge, Overdischarge, Overload |
Noise level | 40 dB |
Output power capacity | 0.8 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces |
---|
USB port | Yes |
AC outlets quantity | 6 AC outlet(s) |
USB 2.0 ports quantity | 2 |
Ethernet LAN (RJ-45) ports | 2 |
USB port type | USB Type-A |
Battery |
---|
Number of batteries supported | 1 |
Battery voltage | 12 V |
Battery capacity | 5 Ah |
Battery recharge time | 8 h |
Typical backup time at full load | 14 min |
Design |
---|
Form factor | Compact |
Product colour | Black |
Safety | CE |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions |
---|
Weight | 2.9 kg |
Width | 158.5 mm |
Height | 95 mm |
Depth | 305 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Certificates |
---|
Safety | CE |
FSP NanoFit 800 uninterruptible power supply (UPS) Standby (Offline) 0.8 kVA 480 W 6 AC outlet(s) Power |
---|
Output voltage regulation | ±10%% |
Output frequency regulation | ±1 Hz |
Output power | 480 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output power capacity | 0.8 kVA |
Performance |
---|
UPS topology | Standby (Offline) |
Waveform | Sine |
Response time | 6 ms |
Surge protection | Yes |
Surge protection features | Network |
Power protection features | Overcharge, Overdischarge, Overload |
Noise level | 40 dB |
Features |
---|
Output frequency | 50/60 Hz |
UPS topology | Standby (Offline) |
Waveform | Sine |
Output voltage regulation | ±10%% |
Output frequency regulation | ±1 Hz |
Response time | 6 ms |
Output power | 480 W |
Input operation voltage (min) | 220 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge protection | Yes |
Surge protection features | Network |
Power protection features | Overcharge, Overdischarge, Overload |
Noise level | 40 dB |
Output power capacity | 0.8 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces |
---|
USB port | Yes |
AC outlets quantity | 6 AC outlet(s) |
USB 2.0 ports quantity | 2 |
Ethernet LAN (RJ-45) ports | 2 |
USB port type | USB Type-A |
Battery |
---|
Number of batteries supported | 1 |
Battery voltage | 12 V |
Battery capacity | 5 Ah |
Battery recharge time | 8 h |
Typical backup time at full load | 14 min |
Design |
---|
Form factor | Compact |
Product colour | Black |
Safety | CE |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 90% |
Technical details |
---|
Output frequency | 50/60 Hz |
Harmonized System (HS) code | 85078000 |
Weight & dimensions |
---|
Weight | 2.9 kg |
Width | 158.5 mm |
Height | 95 mm |
Depth | 305 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Certificates |
---|
Safety | CE |
£77.04 Out of stock
-
Power |
---|
Output voltage regulation | 1% |
Output power | 2700 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 3 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Output voltage regulation | 1% |
Output power | 2700 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 3 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 4 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 6 |
Typical backup time at half load | 9.8 min |
Typical backup time at full load | 3.5 min |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Weight & dimensions |
---|
Weight | 27.6 kg |
Width | 190 mm |
Height | 318 mm |
Depth | 421 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
FSP Champ Tower 3K uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 2700 W Power |
---|
Output voltage regulation | 1% |
Output power | 2700 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 3 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Output voltage regulation | 1% |
Output power | 2700 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 3 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 4 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 6 |
Typical backup time at half load | 9.8 min |
Typical backup time at full load | 3.5 min |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Weight & dimensions |
---|
Weight | 27.6 kg |
Width | 190 mm |
Height | 318 mm |
Depth | 421 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
£462.46 Out of stock
-
Power |
---|
Output voltage regulation | 1% |
Output power | 900 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 110 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 1 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Number of phases | 1 |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output power | 900 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 110 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Number of phases | 1 |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
AC outlets quantity | 3 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 2 |
Battery recharge time(90%) | 4 h |
Design |
---|
Rack capacity | 2U |
Form factor | Rackmount |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Built-in fan | Yes |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cooling |
---|
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions |
---|
Weight | 12 kg |
Width | 438 mm |
Height | 88 mm |
Depth | 310 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Number of phases | 1 |
FSP Champ Rack 1K uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 900 W 3 AC outlet(s) Power |
---|
Output voltage regulation | 1% |
Output power | 900 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 110 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 1 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Number of phases | 1 |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output power | 900 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 110 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Number of phases | 1 |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
AC outlets quantity | 3 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 2 |
Battery recharge time(90%) | 4 h |
Design |
---|
Rack capacity | 2U |
Form factor | Rackmount |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Built-in fan | Yes |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cooling |
---|
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions |
---|
Weight | 12 kg |
Width | 438 mm |
Height | 88 mm |
Depth | 310 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Number of phases | 1 |
£277.61 Out of stock
-
Power |
---|
Output voltage regulation | 1% |
Output power | 1800 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 2 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of phases | 1 |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Output voltage regulation | 1% |
Output power | 1800 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 2 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Number of phases | 1 |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 4 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 4 |
Typical backup time at half load | 9.6 min |
Typical backup time at full load | 3.5 min |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Weight & dimensions |
---|
Weight | 17 kg |
Width | 145 mm |
Height | 220 mm |
Depth | 397 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Number of phases | 1 |
FSP Champ Tower 2K uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 1800 W Power |
---|
Output voltage regulation | 1% |
Output power | 1800 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 2 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of phases | 1 |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Output voltage regulation | 1% |
Output power | 1800 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 2 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Number of phases | 1 |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 4 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 4 |
Typical backup time at half load | 9.6 min |
Typical backup time at full load | 3.5 min |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Weight & dimensions |
---|
Weight | 17 kg |
Width | 145 mm |
Height | 220 mm |
Depth | 397 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Number of phases | 1 |
£349.38 Out of stock
-
Power |
---|
Output voltage regulation | 1% |
Output power | 2700 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 110 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 3 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Number of phases | 1 |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output power | 2700 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 110 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 3 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Number of phases | 1 |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
AC outlets quantity | 3 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 6 |
Battery recharge time(90%) | 4 h |
Design |
---|
Rack capacity | 2U |
Form factor | Rackmount |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Built-in fan | Yes |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cooling |
---|
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions |
---|
Weight | 29.3 kg |
Width | 438 mm |
Height | 88 mm |
Depth | 630 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Number of phases | 1 |
FSP Champ Rack 3K uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 2700 W 3 AC outlet(s) Power |
---|
Output voltage regulation | 1% |
Output power | 2700 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 110 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 3 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Number of phases | 1 |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 1% |
Output power | 2700 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 110 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 3 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Number of phases | 1 |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
AC outlets quantity | 3 AC outlet(s) |
AC outlet types | Type F |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 6 |
Battery recharge time(90%) | 4 h |
Design |
---|
Rack capacity | 2U |
Form factor | Rackmount |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Built-in fan | Yes |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Sustainability compliance | Yes |
Sustainability certificates | CE |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cooling |
---|
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions |
---|
Weight | 29.3 kg |
Width | 438 mm |
Height | 88 mm |
Depth | 630 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Number of phases | 1 |
£619.62RRP £1,096.72Save £477.10
Out of stock
-
Power |
---|
Output voltage regulation | 1% |
Output power | 900 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 1 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of phases | 1 |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Output voltage regulation | 1% |
Output power | 900 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Number of phases | 1 |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 3 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 2 |
Typical backup time at half load | 8.9 min |
Typical backup time at full load | 3.2 min |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Weight & dimensions |
---|
Weight | 9.8 kg |
Width | 145 mm |
Height | 220 mm |
Depth | 282 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Number of phases | 1 |
FSP Champ Tower 1K uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 900 W Power |
---|
Output voltage regulation | 1% |
Output power | 900 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Crest factor | 3:1 |
Output power capacity | 1 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of phases | 1 |
LED indicators | Yes |
Noise level | 50 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 47/63 Hz |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Output voltage regulation | 1% |
Output power | 900 W |
Input operation voltage (min) | 120 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Power factor | 0.99 |
Noise level | 50 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Total Harmonic Distortion (THD) (linear load) | 3% |
Total Harmonic Distortion (THD) (non-linear load) | 6% |
Input frequency | 40 - 70 Hz |
Number of phases | 1 |
Ports & interfaces |
---|
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Number of output IEC jumpers | 3 |
USB port type | USB Type-B |
Battery |
---|
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Number of battery cells | 2 |
Typical backup time at half load | 8.9 min |
Typical backup time at full load | 3.2 min |
Battery recharge time(90%) | 4 h |
Design |
---|
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Control type | Buttons |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 90% |
Technical details |
---|
Output frequency | 47/63 Hz |
Harmonized System (HS) code | 85078000 |
Packaging data |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content |
---|
Batteries included | Yes |
Cables included | Input power cable, USB cable |
Manual | Yes |
Software CD | Yes |
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Weight & dimensions |
---|
Weight | 9.8 kg |
Width | 145 mm |
Height | 220 mm |
Depth | 282 mm |
Logistics data |
---|
Harmonized System (HS) code | 85078000 |
Other features |
---|
Packaging content | UPS, Power cable, USB cable, Software on CD, User manual |
Number of phases | 1 |
£205.90 Out of stock
<